Search   Start
Our Product Recommendations for Power Plants

The table below shows an overview over measuring points in a coal-fired power plant. The data is completed by the measuring tasks and the recommended analyzer devices of our delivery program. In practice, deviations from this example however can arise.

Recommended Products
Measuring point   Tasks   Suitable analyzers   
Coal bunker Protection against smouldering, level monitoring S700, MaihakMBA200, MaihakLOT369
Behind coal mill False air entry control ZIRKOR302, S700
In front of burner Burning air dosage FLOWSIC100
At the burner Combustion optimization, also used for staged air supply denitrification FLOWSIC100
Behind boiler Combustion optimization ZIRKOR302, S700
In front of denitrification Function check of denitrification, emission monitoring GM31, ZIRKOR302, MCS100E
Behind denitrification, in front of electrofilter, in front of desulfurization Function check of denitrification, ammonia slip measurement, protection of electrofilter against explosions, emission monitoring, control od desulfurization (input values) GM31, ZIRKOR302, MCS100E, OMD41, FLOWSIC100
In front of desulfurization, at the electrofilter Humitidy measurement, backflow detection of ash GM35, MaihakMBA200
Behind desulfurization, behind electrofilter, at the stack Function check of desulfurization, protection of the electrofilter against explosions, emission monitoring GM31, S700, MCS100E, ZIRKOR302, GM35, GM950, OMD41, RM230, RM210, FW100, FLOWSIC100
At the stack Emission data acquisition and processing MEAC2000
At the turbo generator Monitoring of generator cooling S700


Contact
Systems Engineering and Integration
SICK MAIHAK, Inc.
15415 International Plaza Drive
Suite 100
Houston, Texas 77032

Phone: 281-436-5100
Fax: 281-436-5200

Administrative Center
SICK MAIHAK, Inc.
6900 West 110th Street
Minneapolis, MN 55438

Phone: 952-941-6780
Fax: 952-941-9287

Fast Lane USA:
information@sickmaihak.com