The table below shows an overview over measuring points in an iron & steel plant. The data is completed by the measuring tasks and the recommended analyzer devices of our delivery program. In practice, deviations from this example however can arise.
Recommended Products |
 |
Measuring point | Tasks | Suitable analyzers |
 |
 |
Cokemaking
|
Personell protection
|
S700
|
 |
 |
Raw material silo
|
Level monitoring
|
MaihakMBA200, MaihakLOT369
|
 |
 |
Coal silo / coke silo
|
Protection against smouldering and explosions
|
S700
|
 |
 |
Raw material hall
|
Personell protection, explosion protection
|
S700, RM230, RM210, OMD41
|
 |
 |
Behind blast furnace
|
Composition of blast furnace gas, control of furnace operation
|
S700
|
 |
 |
Behind dust filter
|
Protection against smouldering
|
S700
|
 |
 |
Blast furnace gas, befor gas outlet
|
Quality and energy content of the blast furnace gas
|
S700
|
 |
 |
Air blast inlet
|
Air ratio, combustion optimization in the blast furnace
|
S700, ZIRKOR302
|
 |
 |
Exhaust gas of hot air stoves
|
Combustion optimization in the hot air stoves
|
GM35, ZIRKOR302, S700, MCS100E
|
 |
 |
Reducing gas inlet of the kiln
|
Composition of the burning and reducing gas, reducing power of the gas, operating parameter
|
S700
|
 |
 |
Gas outlet of the kiln
|
Composition and energy content of furnace gas, operation parameter
|
S700
|
 |
 |
Gas outlet of shaft furnace
|
Composition and energy content of the furnace gas, operation parameter
|
S700
|
 |
 |
Reformer gas
|
Composition of the burning and reducing gas, reducing power of the gas, operating parameter
|
S700
|
 |
 |
Exhaust gas of the reformer
|
Combustion optimization in the reformer
|
GM35, ZIRKOR302, S700, MCS100E
|
 |
 |
Behind basic oxygen furnace or electric arc furnace
|
Degree of decarbonization, degree of oxidation of byproducts, in case of electric arc furnace leakage detection of cooling circuit
|
S700
|
 |
 |
At or in the exhaust gas stack
|
Volume gas flow and temperature as reference value for emission monitoring (definde by local regulations)
|
FLOWSIC100
|
 |
 |
Exhaust gas stack
|
Emission monitoring, data acquisition and processing
|
GM31, GM35, ZIRKOR302, MCS100E, S700, RM230, RM210, MEAC2000
|