Search   Start
 
MCS100E HW
 
 
Emission and raw gas monitoring - also with high acid dew pointmeasuring ranges
The MCS100E HW is an analyzing system for extractive measurement of up to 8 IR-active gas compounds. It can be supplemented with oxygen and FID analyzers. From sampling probe to cell, all components that are in contact with the sample gas are heated to above the dew point and thus protected from corrosion. This hot measurement technique allows the measurement of the water soluble components HCl and NH3.
Applications
  • Emission monitoring of waste incineration plants
  • Monitoring of combustion plants with secondary fuels
  • Process gas monitoring in cement plants
  • Emission monitoring of refineries
  • Emission monitoring of heavy oil fired diesel engines
 
Technical specification
  Analyzer   MCS100E  
  Measuring principle   Gas filter correlation, interference filter correlation, zirconium dioxide sensor  
  Measuring components   CH4, CO, CO2, H2O, HCl, N2O, NH3, NO, NO2, O2, SO2  
  Number of measuring components   8  
  Measuring ranges   CH4: 0 ... 100 mg/m³
CO: 0 ... 75 mg/m³
CO2: 0 ... 25 Vol%
H2O: 0 ... 40 Vol%
HCl: 0 ... 15 mg/m³
N2O: 0 ... 100 mg/m³
NH3: 0 ... 20 mg/m³
NO: 0 ... 200 mg/m³
NO2: 0 ... 100 mg/m³
O2: 0 ... 21 Vol%
SO2: 0 ... 75 mg/m³
 
  Sample gas flow   200 ... 1,000 l/h, depends on application  
  Sample gas temperature   Inlet analyzer system: 0 ... 220 °C (32 ... 428 °F)
In the process: 0 ... 1,300 °C (32 ... 2,372 °F)
 
  Sample gas pressure   900 ... 1,100 hPa, atmospheric  
  Ambient temperature   5 ... 35 °C (41 ... 95 °F)  
  Ambient pressure   900 ... 1,100 hPa  
  Conformities   2000/76/EC, 2001/80/EC, GOST, MCERTS, U.S. EPA compliant  
  Electrical safety   CE  
  Enclosure rating   IP 43  
  Analogue outputs   4 outputs:
0/4 ... 20 mA, 500 Ohm
Max. 64 outputs with opto box via optical fibre possible
 
  Analogue inputs   4 inputs:
0/4 ... 20 mA
Max. 64 inputs with opto box via optical fibre possible
 
  Digital outputs   12 outputs:
40 V, 1 A
Max. 64 outputs with opto box via optical fibre possible
 
  Digital inputs   4 inputs:
50 V AC, 4 A / 24 V DC, 4 A
Max. 64 inputs with opto box via optical fibre possible
 
  Interfaces   RS-232, RS-485
(Additional interfaces on request)
 
  Bus protocol   MODBUS (Additional busses on request)  
  System components   Analyzer MCS100E, analyzer cabinet, sampling probe, sample gas line, sample gas pump  
     
Shopping Cart