MKAS Comfort
|
|
| |
The automatic measuring system for emission monitoring according to EU standards The analyzing system MKAS Comfort includes all major system components like sampling probe, heated sample gas line, 1 or 2-stage gas cooler, sample gas pump, filters and valve block. The specific choice is made according to the needs for an individual application. Together with an analyzer S700 or SIDOR it fulfills all requirements for an automatic measuring system (AMS) according to the recent EU standards. Due to its modular concept it can be extended with additional analyzers or components. Thus, it can be adapted to a wide variety of measuring tasks. Applications
- Emission monitoring according to EU directives
- Measurement in raw and clean gas
- Measurement in process gases
|
|
 |
 |
 |
 |
 |
Technical specification |
 |
 |
| |
Analyzer |
|
S700, SIDOR |
|
 |
 |
 |
| |
Components |
|
CH4, CO, CO2, N2O, NO, NO2, O2, SO2
(The measuring ranges depend on the integrated analyzers and the application.) |
|
 |
 |
 |
| |
Sample gas flow |
|
Standard: 30 ... 60 l/h
With bypass pump: 0 ... 250 l/h |
|
 |
 |
 |
| |
Sample gas temperature |
|
At cabinet inlet: 0 ... 200 °C (32 ... 392 °F)
Process: 0 ... 900 °C (32 ... 1,652 °F)
Depending on probe system |
|
 |
 |
 |
| |
Humidity of sample gas |
|
Dew point: 0 ... 100 °C (32 ... 212 °F) |
|
 |
 |
 |
| |
Ambient temperature |
|
Standard: 5 ... 35 °C (41 ... 95 °F)
Without direct sun exposure
With cooling device: 5 ... 50 °C (41 ... 122 °F) |
|
 |
 |
 |
| |
Ambient humidity |
|
0 ... 95 %
Relative humidity, non-condensing. |
|
 |
 |
 |
| |
Ex-approvals |
|
Ex-types for zone 1 and 2 on request |
|
 |
 |
 |
| |
Electrical safety |
|
CE |
|
 |
 |
 |
| |
Enclosure rating |
|
IP 54
With cooling device: IP 34 for outer cooling circuit |
|
 |
 |
 |
| |
Analogue outputs |
|
Depends on analyzer and system configuration |
|
 |
 |
 |
| |
Analogue inputs |
|
Depends on analyzer and system configuration |
|
 |
 |
 |
| |
Digital outputs |
|
Depends on analyzer and system configuration |
|
 |
 |
 |
| |
Digital inputs |
|
Depends on analyzer and system configuration |
|
 |
 |
 |
| |
Interfaces |
|
Depends on analyzer and system configuration |
|
 |
 |
 |
| |
Device types |
|
GRP cabinet, steel sheet cabinet |
|
 |
 |
 |
| |
System components |
|
Analyzer SIDOR or S710, analyzer cabinet, sample probe, sample gas cooler, sample gas line, sample gas pump, NOx converter |
|
 |
 |
 |
| |
Mounting |
|
Under roofing or other protection against exposure to direct heat radiation, high dust loads and corrosive atmospheres |
|
 |
 |
 |
| |
|
|
|
|
 |
|
 |
|