MKAS Multipoint
 
 
The analyzing system with sample point switching function ranging from 2 to 8 sample points
The analyzing system MKAS Multipoint is especially designed for switching between several measuring points. The sample gas is extracted at the sample point and let to the analyzer cabinet via sample gas line (optional with anti-freeze). Downstream of a gas cooler the switching between the sample points and the analyzer is made using a valve block. A bypass system ensures that the gas paths between sample points and valves are always flushed with measuring gas. Therefore, the switching can be made without a time lag and adsorption/desorption effects in the lines can be avoided. Needless to say, that also this analyzer system has a modular design and can be adapted to the measuring task.
Applications
  • Measurement in raw and clean gas
  • Measurement in process gases
  • Monitoring of process lines
  • Combined monitoring of identical production units
 
Technical specification
  Analyzer   S700, SIDOR  
  Components   CH4, CO, CO2, N2O, NO, NO2, O2, SO2
(The measuring ranges depend on the integrated analyzers and the application.)
 
  Sample gas flow   Standard: 30 ... 60 l/h
With bypass pump: 0 ... 250 l/h
 
  Sample gas temperature   At cabinet inlet: 0 ... 200 °C (32 ... 392 °F)
Process: 0 ... 900 °C (32 ... 1,652 °F)
Depending on probe system
 
  Humidity of sample gas   Dew point: 0 ... 100 °C (32 ... 212 °F)  
  Ambient temperature   Standard: 5 ... 35 °C (41 ... 95 °F)
Without direct sun exposure
With cooling device: 5 ... 50 °C (41 ... 122 °F)
 
  Ambient humidity   0 ... 95 %
Relative humidity, non-condensing.
 
  Ex-approvals   Ex-types for zone 1 and 2 on request  
  Electrical safety   CE  
  Enclosure rating   IP 54
With cooling device: IP 34 for outer cooling circuit
 
  Analogue outputs   Depends on analyzer and system configuration  
  Analogue inputs   Depends on analyzer and system configuration  
  Digital outputs   Depends on analyzer and system configuration  
  Digital inputs   Depends on analyzer and system configuration  
  Interfaces   Depends on analyzer and system configuration  
  Device types   GRP cabinet, steel sheet cabinet  
  System components   Analyzer SIDOR or S710, analyzer cabinet, sample probe, sample gas cooler, sample gas line, sample gas pump, sample point switching, NOx converter  
  Mounting   Under roofing or other protection against exposure to direct heat radiation, high dust loads and corrosive atmospheres  
     