Two in one - Dust monitor with transmittance and scattered light measuring principle
The DUSTHUNTER C200 is a type-approved measuring device which combines the advantages of the measuring principles transmittance and scattered light forward. Therefore, it is ideal for measurement of very low to high dust concentrations. The automatic self-alignment
secures the optimal position of the measuring beam and prevents incorrect measurements with that.An automatic self-alignment. An automatic check of zero and reference point as well as a contamination monitoring is integrated in the device.
Applications
  • Emission monitoring of power stations and waste incineration plants
  • Monitoring of filter plants
  • Measuring the dust concentration in exhaust fumes and waste air channels in front of and after filter
 
Technical specification
  Measuring principle   Scattered light forward, transmissiometry  
  Measuring ranges   Transmittance: 100 ... 90 % / 100 ... 0 %
Opacity: 0 ... 10 % / 0 ... 100 %
Extinction: 0 ... 0.045 / 0 ... 2
Dust content (scattered light): 0 ... 5 mg/m³ / 0 ... 200 mg/m³
Dust content (transmittance): 0 ... 200 mg/m³ / 0 ... 10,000 mg/m³
 
  Measuring paths   0.5 ... 3 m (19.7 ... 118.1 in)
2.5 ... 8 m (98.4 ... 315 in)
 
  Process temperature   -25 ... 300 °C (-13 ... 572 °F), non-condensing;
higher temperatures on request
 
  Process pressure   -50 ... 2 hPa;
other pressure ranges with external purge-air unit on request
 
  Duct diameter   0.5 ... 8 m (19.7 ... 315 in)  
  Ambient temperature   -25 ... 60 °C (-13 ... 140 °F),
max. +45 °C (113 °F) for MCU with purge air unit
 
  Ambient humidity   0 ... 95 %, relative humidity, non-condensing.  
  Conformities   2000/76/EC, 2001/80/EC, GOST, MCERTS, German Clean Air Regulations (TA-Luft)  
  Electrical safety   CE  
  Enclosure rating   IP 66  
  Analogue outputs   3 outputs:
0/2/4 ... 20 mA, 750 Ohm;
further analogue outputs when using I/O modules
 
  Analogue inputs   2 inputs:
0 ... 20 mA, 0 ... 5/10 V;
further analogue inputs when using I/O modules
 
  Digital outputs   5 relay contacts:
120 V AC, 1 A (30 V DC, 2 A);
further digital outputs when using I/O modules
 
  Digital inputs   4 inputs;
further digital inputs when using I/O modules
 
  Interfaces   RS-232, USB 1.1  
  Device types   Cross-duct type  
  System components   Sender/receiver unit, reflector/scattered light receiver, MCU  
  Bus protocol   Ethernet (option)
PROFIBUS-DP (option)
 
     
Shopping Cart