Search   Start
 
DUSTHUNTER SF100
 
 
The type-approved dust monitor as cross-duct version
The DUSTHUNTER SF100 is a type-approved measuring device for dust at very low to high concentrations along the whole duct diameter. The automatic self-alignment secures the optimal position
of the measuring beam and prevents incorrect measurements with that. The measurement is based on the forward scattering of light.
An automatic check of zero and reference point as well as a contamination monitoring is integrated in the device.
Applications
  • Emission monitoring of power stations and waste incineration plants
  • Monitoring of filter plants
  • Monitoring of the dust loads in factory workshops
 
Technical specification
  Measuring principle   Scattered light forward  
  Measuring ranges   Dust content: 0 ... 5 mg/m³ / 0 ... 200 mg/m³;
higher concentrations on request
 
  Measuring paths   Penetration depth: 0.25 ... 0.75 m  
  Process temperature   -25 ... 300 °C (-13 ... 572 °F), non-condensing;
higher temperatures on request
 
  Process pressure   -50 ... 2 hPa;
other pressure ranges with external purge-air unit on request
 
  Duct diameter   0.5 ... 6 m (19.7 ... 236.2 in)  
  Ambient temperature   -25 ... 60 °C (-13 ... 140 °F),
max. +45 °C (113 °F) for MCU with purge air unit
 
  Ambient humidity   0 ... 95 %, relative humidity  
  Conformities   2000/76/EC, 2001/80/EC, GOST, MCERTS, German Clean Air Regulations (TA-Luft), U.S. EPA compliant  
  Electrical safety   CE  
  Enclosure rating   IP 66  
  Analogue outputs   3 outputs:
0/2/4 ... 20 mA, 750 Ohm;
further analogue outputs when using I/O modules
 
  Analogue inputs   2 inputs:
0 ... 20 mA, 0 ... 5/10 V;
further analogue inputs when using I/O modules
 
  Digital outputs   5 relay contacts:
120 V AC, 1 A (30 V DC, 2 A);
further digital outputs when using I/O modules
 
  Digital inputs   4 inputs;
further digital inputs when using I/O modules
 
  Interfaces   RS-232, USB 1.1  
  Operation   Via SOPAS software or LC display (option)  
  Device types   Cross-duct type  
  System components   Sender unit, receiver unit, control unit MCU  
  Test functions   Automatic check of zero and reference point, contamination monitoring  
  Bus protocol   Ethernet (option)
PROFIBUS-DP (option)
 
     
Shopping Cart
Info service