Technical specification |
 |
 |
| |
Measuring principle |
|
Transmissiometry |
|
 |
 |
 |
| |
Measuring ranges |
|
Transmittance: 100 ... 50 % / 100 ... 0 %
Opacity: 0 ... 50 % / 0 ... 100 %
Extinction: 0 ... 0.3 / 0 ... 2
Dust content: 0 ... 1,500 mg/m³ / 0 ... 10,000 mg/m³;
the measuring range for dust concentration depends on path length and dust properties |
|
 |
 |
 |
| |
Measuring paths |
|
1.5 ... 8 m (59.1 ... 315.0 in) |
|
 |
 |
 |
| |
Process temperature |
|
-25 ... 600 °C (-13 ... 1112 °F), non-condensing |
|
 |
 |
 |
| |
Process pressure |
|
-50 ... 2 hPa;
other pressure ranges with external purge-air unit on request |
|
 |
 |
 |
| |
Duct diameter |
|
1.5 ... 8 m (59.1 ... 315.0 in) |
|
 |
 |
 |
| |
Ambient temperature |
|
-25 ... 60 °C (-13 ... 140 °F),
max. +45 °C (113 °F) for MCU with purge air unit |
|
 |
 |
 |
| |
Ambient humidity |
|
0 ... 95 %, relative humidity |
|
 |
 |
 |
| |
Electrical safety |
|
CE |
|
 |
 |
 |
| |
Enclosure rating |
|
IP 66 |
|
 |
 |
 |
| |
Analogue outputs |
|
1 output:
0/2/4 ... 20 mA, 750 Ohm;
further analogue outputs when using I/O modules |
|
 |
 |
 |
| |
Analogue inputs |
|
Analogue inputs when using I/O modules |
|
 |
 |
 |
| |
Digital outputs |
|
3 relay contacts:
120 V AC, 1 A (30 V DC, 2 A);
further digital outputs when using I/O modules |
|
 |
 |
 |
| |
Digital inputs |
|
Digital inputs when using I/O modules |
|
 |
 |
 |
| |
Interfaces |
|
RS-232, USB 1.1 |
|
 |
 |
 |
| |
Operation |
|
Via SOPAS software |
|
 |
 |
 |
| |
Device types |
|
Cross-duct type |
|
 |
 |
 |
| |
System components |
|
Sender/receiver unit, reflector, control
unit MCU |
|
 |
 |
 |
| |
Test functions |
|
Automatic check of zero and reference point |
|
 |
 |
 |
| |
Bus protocol |
|
Ethernet (option)
PROFIBUS-DP (option) |
|
 |
 |
 |
| |
|
|
|
|
 |