Technical specification |
 |
 |
| |
Measuring principle |
|
Scattered light forward |
|
 |
 |
 |
| |
Measuring ranges |
|
Dust content: 0 ... 5 mg/m³ / 0 ... 200 mg/m³ |
|
 |
 |
 |
| |
Process temperature |
|
PVDF probe: 0 ... 120 °C (32 ... 248 °F)
Hastelloy probe: 0 ... 220 °C (32 ... 428 °F) |
|
 |
 |
 |
| |
Process pressure |
|
-20 ... 20 hPa |
|
 |
 |
 |
| |
Process gas velocity |
|
4 ... 20 m/s (13.1 ... 65.6 ft/s) |
|
 |
 |
 |
| |
Process gas humidity |
|
Max. 10 g/m³ liquid water without water vapor |
|
 |
 |
 |
| |
Ambient temperature |
|
-20 ... 50 °C |
|
 |
 |
 |
| |
Ambient humidity |
|
0 ... 95 %, relative humidity, non-condensing. |
|
 |
 |
 |
| |
Conformities |
|
2000/76/EC, 2001/80/EC, 27. BImSchV., MCERTS, German Clean Air Regulations, U.S. EPA compliant |
|
 |
 |
 |
| |
Electrical safety |
|
CE |
|
 |
 |
 |
| |
Enclosure rating |
|
IP 54
Electronics enclosure: IP 65 |
|
 |
 |
 |
| |
Analogue outputs |
|
1 output:
0/2/4 ... 20 mA, 750 Ohm;
electrically isolated; second output as an option |
|
 |
 |
 |
| |
Digital outputs |
|
4 relay contacts:
250 V, 1 A;
preset for malfunction, warning, limit value and
maintenance |
|
 |
 |
 |
| |
Digital inputs |
|
1 input;
floating contact for maintenance switch |
|
 |
 |
 |
| |
Interfaces |
|
RS-232 |
|
 |
 |
 |
| |
Device type |
|
Cross duct type |
|
 |
 |
 |
| |
System components |
|
Sampling probe, measuring and control cabinet, blower unit |
|
 |
 |
 |
| |
Test functions |
|
Automatic check of zero and reference point |
|
 |
 |
 |
| |
|
|
|
|
 |