Search   Start
 
SHC500, Gravimat
 
 
Mobile dust measuring system
For control and gravimetric comparison measurements on dust concentration monitors. A partial gas flow is sucked off isokinetically via a filter head probe (control in real time). The dust content ist determined by weighting the dust collector mass before and after extraction.
 
Technical specification
  Measuring values   Dust concentration in mg/m³ (operation state, standard state)  
  Measuring range   0 ... 50,000 mg/m³ (0 ... 21.85 gr/ft³)  
  Measurement principle   Gravimetry  
  Compliance   VDI Guideline 2066, ISO 9096, EN 13284-1, EPA method 17  
  Protection category   IP 54 (automatic unit open; closed IP 65)  
  Interface   RS232  
  System modules   Filter head probe, case with set of dust collectors, automatic unit, (laptop)  
  Test function   Self-testing function  
  Remarks  
  • Compact measuring system, easy to transport
  • No dust loss at the handling by patented dust sampling system. Allows high measuring precision also at low dust concentrations.
  • Automatic test value recording, system control and measurement storage.
  • Real time isokinetic control
  • Measurement results are immediately available after dust sampling (type dependent also automatic)
 
     