OMD41
|
|
| |
Dust and Opacity Monitor For monitoring dust concentrations in industrial plants - even across long measurement paths. The OMD41 is a transmissiometer that operates according to the autocollimator principle. It is performance-tested pursuant to the German Clean Air Regulations, Federal German Pollution Control Act (13th Implementing Ordinance), GOST and the US EPA guidelines.
Applications Asphalt mixing plants; cement manufacture; monitoring/controlling electronic filters; power stations, steel and glass industry; monitoring technical equipment downstream of filter systems
|
|
 |
 |
 |
 |
 |
Technical specification |
 |
 |
| |
Measuring values |
|
Transmission, opacity, extinction, dust concentration |
|
 |
 |
 |
| |
Measuring range |
|
transmission 100 ... 0 %
opacity 0 ... 100 %
extinction 0 ... 2 |
|
 |
 |
 |
| |
Measuring path |
|
0.5 ... 15 m (1.6 ... 49.2 ft) |
|
 |
 |
 |
| |
Measurement principle |
|
Transmission |
|
 |
 |
 |
| |
Measuring gas temperature |
|
600 °C (1,968 °F) max. |
|
 |
 |
 |
| |
Compliance |
|
TÜV approved according to the German Clean Air Regulations, Federal German Pollution Control Act (13th Implementing Ordinance, GOST and U.S. EPA compliant |
|
 |
 |
 |
| |
Protection category |
|
IP 65 |
|
 |
 |
 |
| |
Measured value output |
|
2 analog outputs: 0/2/4 ... 20 mA |
|
 |
 |
 |
| |
Interfaces |
|
RS232, RS422 |
|
 |
 |
 |
| |
Status / control signals |
|
Relay outputs for status signals |
|
 |
 |
 |
| |
System modules |
|
Transmitter/receiver unit, reflector unit, connection unit and air purge unit |
|
 |
 |
 |
| |
Test function |
|
Automatic control cycle and linearity test |
|
 |
 |
 |
| |
Remarks |
|
- Large duct diameters up to 15 m (49.2 ft)
- Automatic check cycle, contamination measurement, correction and zero-point adjustment for transmitter/ receiver and reflector unit
- Integrated linearity check
|
|
 |
 |
 |
| |
|
|
|
|
 |
|
 |
|