Search   Start
 
RM230
 
 
Dust Monitor with AutoRANGE
Based on the scattered light measuring principle, the RM230 detects dust concentrations within a range of < 0.5 to 200 mg/m³ (< 2.2e-4 to 0.087 gr/ft³). Suitable device versions with different measuring penetration depths are available for output of representative measurement results.
Applications
The highly flexible RM230, with its robust design, is ideal for use in harsh industrial environments, e.g. for measurement in clean gas uptstream of electro-static precipitators or fabric filters, for monitoring of exhaust and fresh air systems ofr for protection of gas turbines.
 
Technical specification
  Measuring values   dust concentration  
  Measuring range   smallest range: 0 ... 0.5 mg/m³ (0 ... 2.2e-4 gr/ft³)
largest range: 0 ... 200 mg/m³ (0 ... 0.087 gr/ft³)
 
  Accuracy   2 % of full scale value  
  Measurement principle   scattered light (back scattering)  
  Measuring gas temperature   up to 500 °C (932 °F) higher on request  
  Protection category   IP 65  
  Measured value output   2 analog outputs: 0 ... 20 mA  
  Interfaces   RS232, RS422  
  Status / control signals   4 relay outputs: 48 V DC / 1 A; adjustable
4 status inputs: 10 ... 35 V DC / 10 ... 25 V AC; adjustable
 
  System modules   transmitter/receiver unit, light absorber and connection unit  
  Test function   Automatic linearity check  
  Remarks   Device versions with different measuring penetration depths depending on the stack diameter are available:
  • version 1: for Ø 0.2 … 1.5 m (0.7 … 5 ft)
  • version 2: for Ø 1.5 … 3.5 m (5 … 11.5 ft)
  • version 3: for Ø > 3.5 m (> 11.5 ft)
 
     