Search   Start
FLOWSIC100 Series
Thanks to its modular design, the FLOWSIC100 series can be used in many applications. To application possibilities of the diverse FLOWSIC100 devices see Info service.
Emissions monitoring
Continuous, non-contact, and direct - the FLOWSIC100 devices supply accurate and reliable measurements of the volume flow and gas velocity in flue-gas, exhaust-gas ducts or chimneys. They fulfill the requirements of the German Clean Air Regulations and the Federal German Pollution Control Act (13th, 17th and 27th Impl. Ordinances).
Process measurement
The reliability, precision, and short response times of the FLOWSIC100 series significantly enhance the efficiency of open and closed-loop control circuits. The instantaneous flow measurement reflect the current process status - even under difficult conditions, such as high temperatures or pressures.
Flare gas measurement
For FLOWSIC100 Flare an innovative sensor design was developed. The ultrasonic transducer is embedded in a flow optimized sensor shape - qualified for high speed gas conditions. The unique design reduces flow noise and signal drift to a minimum and enables stable and reliable results at very high gas velocities.

FLOWSIC100 Devices
                 Device                     Inner channel diameter   Gas temperature   Process pressure   
- - - Process measurement - - -
FLOWSIC100 CL150 0.15 ... 1.7 m -40 ... +260 °C 0 ... 16 bar
FLOWSIC100 EX-CL150 0.15 ... 1.7 m -40 ... +260 °C 0 ... 16 bar
FLOWSIC100 EX-CL150-RE 0.15 ... 1.7 m -40 ... +260 °C 0 ... 16 bar
FLOWSIC100 EX-PN16 0.15 ... 1.7 m -40 ... +260 °C 0 ... 16 bar
FLOWSIC100 EX-PN16-RE 0.15 ... 1.7 m -40 ... +260 °C 0 ... 16 bar
FLOWSIC100 EX-Z2-CL150 0.15 ... 1.7 m -40 ... +260 °C 0 ... 16 bar
FLOWSIC100 EX-Z2-CL150-RE 0.15 ... 1.7 m -40 ... +260 °C 0 ... 16 bar
FLOWSIC100 EX-Z2-PN16 0.15 ... 1.7 m -40 ... +260 °C 0 ... 16 bar
FLOWSIC100 EX-Z2-PN16-RE 0.15 ... 1.7 m -40 ... +260 °C 0 ... 16 bar
FLOWSIC100 PN16 0.15 ... 1.7 m -40 ... +260 °C 0 ... 16 bar
FLOWSIC100 PR-EX-Z2 > 0.4 m -40 ... +260 °C -100 ... +100 hPa
- - - Flare gas measurement - - -
FLOWSIC100 EX 0.1 ... 1.8 m -70 ... 280 °C -0.5 ... 16 barg
FLOWSIC100 EX-S 0.1 ... 1.8 m -70 ... 280 °C -0.5 ... 16 barg
FLOWSIC100 EX-PR 0.3 ... 1.8 m -70 ... 280 °C -0.5 ... 16 barg
- - - Emission measurement - - -
FLOWSIC100 H 1.4 ... 13.0 m -40 ... +260 °C -100 ... +100 hPa
FLOWSIC100 H-AC 1.4 ... 11.3 m -40 ... +450 °C -100 ... +100 hPa
FLOWSIC100 M 0.15 ... 3.4 m -40 ... +260 °C -100 ... +100 hPa
FLOWSIC100 M-AC 0.15 ... 3.4 m -40 ... +450 °C -100 ... +100 hPa
FLOWSIC100 PH 0.7 ... 8.7 m -40 ... +450 °C -100 ... +100 hPa
FLOWSIC100 PH-S 1.4 ... 11.3 m -40 ... +450 °C -100 ... +100 hPa
FLOWSIC100 PM 0.35 ... 2.5 m -40 ... +450 °C -100 ... +100 hPa
FLOWSIC100 PR > 0.4 m -40 ... +260 °C -100 ... +100 hPa
FLOWSIC100 PR-AC > 0.4 m -40 ... +350 °C -100 ... +100 hPa
FLOWSIC100 S 0.15 ... 1.3 m -40 ... +150 °C -100 ... +100 hPa


Contact
Systems Engineering and Integration
SICK MAIHAK, Inc.
15415 International Plaza Drive
Suite 100
Houston, Texas 77032

Phone: 281-436-5100
Fax: 281-436-5200
Administrative Center
SICK MAIHAK, Inc.
6900 West 110th Street
Minneapolis, Minnesota 55438

Phone: 952-941-6780
Fax: 952-941-9287
Fast Lane USA:
information@sickmaihak.com
Info service