Search   Start
FLOWSIC100 Series
Thanks to its modular design, the FLOWSIC100 series can be used in many applications. To application possibilities of the diverse FLOWSIC100 devices see Info service.
Emissions monitoring
Measuring gas flow in stacks of over 10 feet or more is practically impossible without ultrasound.
Now, there is FLOWSIC100 H which provides excellent, reliable measurements in large ducts with only a single pair of transducers. FLOWSIC100 flow measurement systems are EPA compliant and confirm to all standard guidelines worldwide.
Process measurement
The FLOWSIC100 Process version offers outstanding gas flow measurement technology for process control. The highly durable titanium sensors give superior performance even when faced with corrosive media and high temperatures. We provice a devices suitable for installation in hazardous areas as well as retractable systems for high pressure applications.

All FLOWSIC100 devices measure gas velocity, temperature, volume flow and sound velocity.
FLOWSIC100 Devices
                Device                   Inner channel diameter   Gas temperature   Application   
FLOWSIC100 CL150 0.15 ... 1.7 m
(0.49 ... 5.58 ft)
-40 ... +260 °C
(-40 ... 500 °F)
Process
FLOWSIC100 EX-CL150 0.15 ... 1.7 m
(0.49 ... 5.58 ft)
-40 ... +260 °C
(-40 ... 500 °F)
Process
FLOWSIC100 EX-CL150-RE 0.15 ... 1.7 m
(0.49 ... 5.58 ft)
-40 ... +260 °C
(-40 ... 500 °F)
Process
FLOWSIC100 EX-Z2-CL150 0.15 ... 1.7 m
(0.49 ... 5.58 ft)
-40 ... +260 °C
(-40 ... 500 °F)
Process
FLOWSIC100 EX-Z2-CL150-RE 0.15 ... 1.7 m
(0.49 ... 5.58 ft)
-40 ... +260 °C
(-40 ... 500 °F)
Process
FLOWSIC100 H 1.4 ... 13.0 m
(4.59 ... 42.65 ft)
-40 ... +260 °C
(-40 ... 500 °F)
Emission
FLOWSIC100 H-AC 1.4 ... 11.3 m
(4.59 ... 37.07 ft)
-40 ... +450 °C
(-40 ... 842 °F)
Emission
FLOWSIC100 M 0.15 ... 3.4 m
(0.49 ... 11.15 ft)
-40 ... +260 °C
(-40 ... 500 °F)
Emission
FLOWSIC100 M-AC 0.15 ... 3.4 m
(0.49 ... 11.15 ft)
-40 ... +450 °C
(-40 ... 842 °F)
Emission
FLOWSIC100 PH 0.7 ... 8.7 m
(2.30 ... 28.54 ft)
-40 ... +450 °C
(-40 ... 842 °F)
Emission
FLOWSIC100 PH-S 1.4 ... 11.3 m
(4.59 ... 37.07 ft)
-40 ... +450 °C
(-40 ... 842 °F)
Emission
FLOWSIC100 PM 0.35 ... 2.5 m
(1.15 ... 8.20 ft)
-40 ... +450 °C
(-40 ... 842 °F)
Emission
FLOWSIC100 PN16 0.15 ... 1.7 m
(0.49 ... 5.58 ft)
-40 ... +260 °C
(-40 ... 500 °F)
Process
FLOWSIC100 EX-PN16 0.15 ... 1.7 m
(0.49 ... 5.58 ft)
-40 ... +260 °C
(-49 ... 500 °F)
Process
FLOWSIC100 EX-PN16-RE 0.15 ... 1.7 m
(0.49 ... 5.58 ft)
-40 ... +260 °C
(-40 ... 500 °F)
Process
FLOWSIC100 EX-Z2-PN16 0.15 ... 1.7 m
(0.49 ... 5.58 ft)
-40 ... +260 °C
(-40 ... 500 °F)
Process
FLOWSIC100 EX-Z2-PN16-RE 0.15 ... 1.7 m
(0.49 ... 5.58 ft)
-40 ... +260 °C
(-40 ... 500 °F)
Process
FLOWSIC100 PR > 0.4 m
(> 1.31 ft)
-40 ... +260 °C
(-40 ... 500 °F)
Emission
FLOWSIC100 PR-AC > 0.4 m
(> 1.31 ft)
-40 ... +350 °C
(-40 ... 662 °F)
Emission
FLOWSIC100 PR-EX-Z2 > 0.4 m
(> 1.31 ft)
-40 ... +260 °C
(-40 ... 500 °F)
Process
FLOWSIC100 S 0.15 ... 1.3 m
(0.49 ... 4.27 ft)
-40 ... +150 °C
(-40 ... 302 °F)
Emission


Contact
Systems Engineering and Integration
SICK MAIHAK, Inc.
15415 International Plaza Drive
Suite 100
Houston, Texas 77032

Phone: 281-436-5100
Fax: 281-436-5200
Administrative Center
SICK MAIHAK, Inc.
6900 West 110th Street
Minneapolis, Minnesota 55438

Phone: 952-941-6780
Fax: 952-941-9287
Fast Lane USA:
information@sickmaihak.com
Info service