Search   Start
 
FLOWSIC100 H-AC
 
 
Gas Flow Measurement for Continuous Emission Monitoring
FLOWSIC100 -The reliable and precise flow measurement with highest demands on durability
With the device type FLOWSIC100 H-AC measurements can be carried out with high power for large stacks up to 13 m (42.65 ft) diameters. The device is suitable for high dust applications and operates at gas temperatures up to 450 °C (842 °F) because of its innovative internal cooling.
This device is certificated according to 2001/80/EC, 2000/76/EC, 27th BImSchV (Federal Immission Control Ordinance) as well as TA air.
Areas of application
Power generation (e. g. power plants), processing industries (cement manufacturing, steel and iron production), waste disposal industry (e. g. waste incineration plants), chemical industry, petrochemical plants and refineries, pulp, paper and textile industry, ventilation and heating plants
 
Technical specification
    Sender/Receiver Unit  
  Measuring values   Gas velocity in m/s (ft/s), volume flow in m³/h (ft³/h) operation and standard state, temperature in °C (°F)  
  Measurement principle   Ultrasonic propagation time delay measurement  
  Measuring range   0 ... +/- 40 m/s (0 ... +/-131 ft/s)  
  Measuring section   2.0 ... 13.0 m (6.56 ... 42.65 ft)  
  Inner channel diameter   1.4 ... 11.3 m (4.59 ... 37.07 ft)  
  Gas temperature   -40 ... +450 °C (-40 ... 842 °F)  
  Mounting angle   45° ... 60°  
  Channel internal pressure   -100 ... +100 hPa (-1450 ... 1450 PSI)  
  Max. dust loading   100 g/m³ (43.70 gr/ft³)  
  Ambient temperature   Sender/Receiver unit: -40 ... +60 °C (-40 ... 140 °F)
Control unit: -40 ... +60 °C (-40 ... 140 °F)
 
  Protection category   IP 65  
    Control Unit MCU  
  Analog output signals   0/2/4 ... 22 mA, max. 750 ohm apparent ohmic resistance, 12 bit resolution
option: more analog outputs via additional I/O-modules
 
  Analog input signals   2 inputs 0 ... 5/10 V or 0/2/4 ... 22 mA (without galvanic isolation), 10 bit resolution  
  Digital output signals   5 potential-free relais outputs (changers) for status signals operating/malfunction, limit value, warning, maintenance, control cycle
option: more digital outputs via additional I/O-modules
 
  Digital input signals   4 potential-free contacts for link to maintenance switch, actuate control cycle, separate zero-point monitoring, separate span test  
  Interfaces   USB 1.1, RS232  
  Buses   option: Profibus, Ethernet  
Shopping Cart
Info service