Gas Flow Measurement for Continuous Emission Monitoring FLOWSIC100 -The reliable and precise flow measurement with highest demands on durability With the device type FLOWSIC100 M measurements can be carried out with medium power - best suitable for stack diameters up to 3.4 m (11.15 ft). This device is certificated according to 2001/80/EC, 2000/76/EC, 27th BImSchV (Federal Immission Control Ordinance) as well as TA air. Areas of application Power generation (e. g. power plants), processing industries (cement manufacturing, steel and iron production), waste disposal industry (e. g. waste incineration plants), chemical industry, petrochemical plants and refineries, pulp, paper and textile industry, ventilation and heating plants
|
|
 |
 |
 |
 |
 |
Technical specification |
 |
 |
| |
|
|
Sender/Receiver Unit |
|
 |
 |
 |
| |
Measuring values |
|
Gas velocity in m/s (ft/s), volume flow in m³/h (ft³/h) operation and standard state, temperature in °C (°F) |
|
 |
 |
 |
| |
Measurement principle |
|
Ultrasonic propagation time delay measurement |
|
 |
 |
 |
| |
Measuring range |
|
0 ... +/- 40 m/s (0 ... +/-131 ft/s) |
|
 |
 |
 |
| |
Measuring section |
|
0.2 ... 4.0 m (0.66 ... 13.12 ft) |
|
 |
 |
 |
| |
Inner channel diameter |
|
0.15 ... 3.4 m (0.49 ... 11.15 ft) |
|
 |
 |
 |
| |
Gas temperature |
|
-40 ... +260 °C (-40 ... 500 °F) |
|
 |
 |
 |
| |
Mounting angle |
|
45° ... 60° |
|
 |
 |
 |
| |
Channel internal pressure |
|
-100 ... +100 hPa (-1450 ... 1450 PSI) |
|
 |
 |
 |
| |
Max. dust loading |
|
1 g/m³ (0.4370 gr/ft³) |
|
 |
 |
 |
| |
Ambient temperature |
|
Sender/Receiver unit: -40 ... +60 °C (-40 ... 140 °F)
Control unit: -40 ... +60 °C (-40 ... 140 °F)
|
|
 |
 |
 |
| |
Protection category |
|
IP 65 |
|
 |
 |
 |
| |
|
|
Control Unit MCU |
|
 |
 |
 |
| |
Analog output signals |
|
0/2/4 ... 22 mA, max. 750 ohm apparent ohmic resistance, 12 bit resolution
option: more analog outputs via additional I/O-modules |
|
 |
 |
 |
| |
Analog input signals |
|
2 inputs 0 ... 5/10 V or 0/2/4 ... 22 mA (without galvanic isolation), 10 bit resolution |
|
 |
 |
 |
| |
Digital output signals |
|
5 potential-free relais outputs (changers) for status signals operating/malfunction, limit value, warning, maintenance, control cycle
option: more digital outputs via additional I/O-modules |
|
 |
 |
 |
| |
Digital input signals |
|
4 potential-free contacts for link to maintenance switch, actuate control cycle, separate zero-point monitoring, separate span test |
|
 |
 |
 |
| |
Interfaces |
|
USB 1.1, RS232 |
|
 |
 |
 |
| |
Buses |
|