FLOWSIC100 PR-EX-Z2
|
|
| |
Volume Flow Measurement for Process Applications Easy installation - wide measuring range - reliable and precise measurement With the device type FLOWSIC100 PR-EX-Z2 measurements can be carried out with ambient pressures up to 0.1 bar (1.45 PSI). Therefor materials of hermetically sealed stainless steel or titanium are available. The installation is carried out from one side only.
This device is constructed as Ex-protected version for use in hazardous area zone 2 according to ATEX guideline 94/9/EC (version for zone 1 on request). |
 |
|
Areas of application Natural gas industry, chemical and plastics manufacturing industry, petrochemical industry and refineries, processing industries (cement manufacturing, steel and iron production), pharmaceutical industry, glass industry, food industry
|
|
 |
 |
 |
 |
 |
Technical specification |
 |
 |
| |
|
|
Sender/Receiver Unit |
|
 |
 |
 |
| |
Measuring values |
|
Gas velocity in m/s (ft/s), volume flow in m³/h (ft³/h) operation and standard state, temperature in °C (°F) |
|
 |
 |
 |
| |
Measurement principle |
|
Ultrasonic propagation time delay measurement |
|
 |
 |
 |
| |
Measuring range |
|
0 ... +/- 40 m/s (0 ... +/-131 ft/s) |
|
 |
 |
 |
| |
Measuring section |
|
0.27 ... 0.28 m (0.89 ... 0.92 ft), fix |
|
 |
 |
 |
| |
Inner channel diameter |
|
> 0.4 m (> 1.31 ft) |
|
 |
 |
 |
| |
Gas temperature |
|
-40 ... +260 °C (-40 ... +500 °F) |
|
 |
 |
 |
| |
Mounting angle |
|
45° |
|
 |
 |
 |
| |
Channel internal pressure |
|
-100 ... +100 hPa (-1450 ... +1450 PSI) |
|
 |
 |
 |
| |
Max. dust loading |
|
1 g/m³ (0.4370 gr/ft³) |
|
 |
 |
 |
| |
Ambient temperature |
|
Sender/Receiver unit: -40 ... +60 °C (-40 ... +140 °F)
Control unit: -40 ... +60 °C (-40 ... +140 °F)
|
|
 |
 |
 |
| |
Protection category |
|
IP 65 |
|
 |
 |
 |
| |
Explosion protection |
|
Europe (ATEX):
- II 3 G EEx nA e IIC T4 (factory certified)
|
|
 |
 |
 |
| |
|
|
Control Unit MCU |
|
 |
 |
 |
| |
Explosion protection |
|
- standard
- optional for using in Ex zone 2: ATEX II3 G EEx nA nC IIC T4 (factory certified) |
|
 |
 |
 |
| |
Analog output signals |
|
0/2/4 ... 22 mA, max. 750 ohm apparent ohmic resistance, 12 bit resolution
option: more analog outputs via additional I/O-modules |
|
 |
 |
 |
| |
Analog input signals |
|
2 inputs 0 ... 5/10 V or 0/2/4 ... 22 mA (without galvanic isolation), 10 bit resolution |
|
 |
 |
 |
| |
Digital output signals |
|
5 potential-free relais outputs (changers) for status signals operating/malfunction, limit value, warning, maintenance, control cycle
option: more digital outputs via additional I/O-modules |
|
 |
 |
 |
| |
Digital input signals |
|
4 potential-free contacts for link to maintenance switch, actuate control cycle, separate zero-point monitoring, separate span test |
|
 |
 |
 |
| |
Interfaces |
|
USB 1.1, RS232 |
|
 |
 |
 |
| |
Buses |
|
option: Profibus, Ethernet |
|
 |
 |
 |
| |
|
|
|
|
 |
|
 |
|