Technical specification |
 |
 |
| |
Measuring values |
|
gas velocity, volume flow (o.s.), volume flow (s.s.), gas temperature, absolute pressure, sound velocity |
|
 |
 |
 |
| |
Measuring range
(actual volumetric flow) |
|
1 and 3 measuring paths: 0 ... 150 l/s (5.3 ft³/s), 70 mm (2.8 in) inner pipe diameter
4 measuring paths: 0 ... 300 l/s (10.6 ft³/s), 100 mm (3.9 in) inner pipe diameter
other pipe diameters / higher flow rates on request |
|
 |
 |
 |
| |
Pulse rate |
|
1 x 80/s (1 path)
3 x 30/s (3 paths)
4 x 30/s (4 paths) |
|
 |
 |
 |
| |
Accuracy typical |
|
< ±2.5 % of measured value, 0.1 Qmax ... Qmax (1 path)
< ±0.7% of measured value, 0.05 Qmax ... Qmax (3 paths)
< ±0.5% of measured value, 0.05 Qmax ... Qmax (4 paths) |
|
 |
 |
 |
| |
Gas velocity |
|
0 ... 40 m/s (0 ... 131 ft/s); higher values on request |
|
 |
 |
 |
| |
Pressure |
|
660 ... 1100 hPa (9.6 ... 16 PSI) |
|
 |
 |
 |
| |
Gas temperature |
|
max. 300 °C (572 °F) (< 10min/h for max. 100 cycles), higher values on request |
|
 |
 |
 |
| |
Transducer temperature |
|
max. 280 °C (536 °F), higher values on request |
|
 |
 |
 |
| |
Measured value output |
|
0 / 2 / 4 ... 20 mA, max. load 750 Ohm;
update rate 10/s |
|
 |
 |
 |
| |
Interface |
|
RS232 (Modbus/AK), update rate: 10/s
RS232 programmable update rate, for parameter setting via PC |
|
 |
 |
 |
| |
Process connection |
|
thread G 2 1/2" (1 and 3 paths),
thread G 4" (4 paths),
others on request |
|
 |
 |
 |
| |
Power supply |
|
90 ... 140 V AC, 50/60 Hz or 190 ... 260 V AC, 50/60 Hz, adjustable
approx. 700 W (1 and 3 paths)