Search   Start
 
DEFOR
 
 
Single or simultaneous measurement of SO2, NO, NO2, Cl2, NH3, CS2, COS, H2S and others gases
The DEFOR is an extractive UV gas analyzer for simultaneous measurement of up to three components. It is a specialist for extremely selective NO-measurements of small ranges. It is a generalist for many UV-active gases like SO2, NO2, Cl2, NH3, CS2, H2S and COS. It shows no cross-sensitivities to CO2 and H2O due to the used spectral range. The innovative signal processing as well as the highly stable detectors provide an outstandingly longterm stability and allow the compensation of drifts and other effects. The state-of-the-art electronics and software provide the required interfaces for remote control via networks and integration into process control systems.
Applications
  • Cl2-measurement, also in combination with O2
  • Measurement of sulfur compound in process gases
  • NO, NO2 and NH3 measurement in nitric acid synthesis
  • H2S and SO2 measurement in sulfur recovery plants
  • Measurement of high H2S concentrations in reactive and acidic gases
  • Measurement of H2 in Cl2 or vice versa
 
Technical specification
  Measuring principle   NDUV spectroscopy  
  Measuring components   Cl2, COS, CS2, H2S, NH3, NO, NO2, SO2  
  Number of components   3  
  Measuring ranges   Cl2: 0 ... 125 ppm / 0 ... 100 vol%
COS: 0 ... 250 ppm / 0 ... 100 vol%
CS2: 0 ... 50 ppm / 0 ... 30 vol%
H2S: 0 ... 25 ppm / 0 ... 100 vol%
NH3: 0 ... 50 ppm / 0 ... 100 vol%
NO: 0 ... 10 ppm / 0 ... 100 vol%
NO2: 0 ... 10 ppm / 0 ... 100 vol%
SO2: 0 ... 10 ppm / 0 ... 100 vol%
 
  Sample gas temperature   0 ... 45 °C (32 ... 113 °F)  
  Sample gas pressure   -200 ... 300 hPa, refering to ambient pressure  
  Ambient temperature   5 ... 45 °C (41 ... 113 °F)  
  Ex-approvals   Wall mounting enclosure: II 2 G Ex px IIC T6; II 3 G Ex nR IIC T6; II 3 G Ex pz IIC T6  
  Electrical safety   CE, EMC, LVD  
  Enclosure rating   19"-rack: IP 40
wall mounting enclosure: IP 65
 
  Analogue outputs   4 outputs:
0/2/4 ... 20 mA, 500 Ohm, electrically isolated
 
  Analogue inputs   2 inputs:
0 ... 20 mA, not electrically isolated
 
  Digital outputs   8 outputs:
34 V AC, 0.5 A 48 V DC, 0.5 A
 
  Digital inputs   8 inputs:
42 V, all inlets with common GND
 
  Interfaces   Ethernet, extendanble via interfaces of the SCU control unit  
  Bus protocol   OPC (Option), via SOPAS  
  Operation   via display or software SOPAS  
  Device types   19''-rack, wall mounting enclosure  
  Test functions   optional adjustment unit  
     
Shopping Cart