Search   Start
 
GM31
 
 
Multi-component analyzer for SO2, NO, NH3 or NO2
The GM31 is suitable for both simultaneous or individual measurements and can be used to measure emissions in flue-gas desulphurization and DeNOx plants.
Applications
Instant and reliable measurement of SO2, NO, NH3 or NO2 and gas temperature (O2 optional) for example in power stations, cement industry, waste incineration plants, petrochemical industries and chemical industries.
 
Technical specification
  Measuring components   SO2, NO, NH3, NO2, Temp., O2 (Option)  
  Measuring range   SO2: 70 ... 30.000 mg/m³ (0.03 ... 13.1 gr/ft³)
NO: 130 ... 4000 mg/m³ (0.06 ... 1.7 gr/ft³)
NH3: 30 ... 100 mg/m³ (0.01 ... 0.04 gr/ft³)
NO2: 100 ... 4000 mg/m³ (0.04 ... 1.7 gr/ft³)
 
  Measurement principle   Transmittance (UV-spectroscopy)  
  Measuring gas temperature   500 °C (932 °F), 550 °C max. (1022 °F max.)  
  Compliance   TÜV approved according to German Clean Air Regulations, Federal German Pollution Control Act (13th, 17th Implementing Ordinance), GOST, U.S. EPA compliant  
  Protection category   IP 65 (IP 20 for control unit in control panel version)  
  Measured value output   4 analog outputs: 0/2/4 ... 20 mA  
  Interfaces   RS232, RS422  
  Status / control signals   Relay outputs for status signals  
  System modules   Transmitter/receiver unit, measuring probe, control unit, air purge unit  
  Test function   Automatic control cycle and linearity test  
  Remarks  
  • Fast and continuous measurements – directly in the gas-carrying duct
  • O2 measurements easy possible by connecting an external sensor
  • Calculated value output (mg/m3 in operating/standard state, ppm)
 
     
Shopping Cart
Info service