GM950
|
|
| |
Rapid CO sensor system The carbon monoxide measuring system GM950 from SICK MAIHAK is in particular suitable for monitoring of fast CO concentration changes. Due to the short response time the GM950 is able to measure almost delay-free rapid increasing concentration peaks of CO or other combustible gases. The GM950 is modular designed so that a flexible configuration of the system components is possible. Applications
- Cement industry: precipitator protection against fast increasing CO peaks by measuring of CO in raw gas (precipitator inlet)
- Furnace plants: combustion process control, minimization of aggressive pollutants
- Availability increase of combustion plants, e.g. by monitoring the CO concentration in boilers
|
|
 |
 |
 |
 |
 |
Technical specification |
 |
 |
| |
Measuring component |
|
CO |
|
 |
 |
 |
| |
Measuring range |
|
0.1 ... 5 vol% |
|
 |
 |
 |
| |
Measurement principle |
|
Automatic calibration of voltage probes (ZrO2) |
|
 |
 |
 |
| |
Measuring gas temperature |
|
600 °C (1,112 °F) max. in continuous operation with compressed air cooling |
|
 |
 |
 |
| |
Protection category |
|
Analysis cabinet IP 54, evaluation unit IP 65 |
|
 |
 |
 |
| |
Measured value output |
|
0/2/4 ... 20 mA analog output |
|
 |
 |
 |
| |
Interfaces |
|
RS232, RS422/485 |
|
 |
 |
 |
| |
Status / control signals |
|
Relay outputs for status signals |
|
 |
 |
 |
| |
System modules |
|
2 CO-sensors, sampling probe, analysis cabinet, evaluation unit |
|
 |
 |
 |
| |
Test function |
|
Self-testing function |
|
 |
 |
 |
| |
Remarks |
|
- Direct CO measurement combustion boilers
- Filter protection due to fast increasing CO peaks
- Simple installation, startup and maintenance
|
|
 |
 |
 |
| |
|
|
|
|
 |
|
 |
|