MCS300P
 
 
Simultaneous process monitoring of up to 6 measuring components
The MCS300P is an extractive process photometer for measurement of gaseous or liquid media. It measures IR- and VIS-active components with variable measuring ranges from very low (ppm) to high (vol%) concentrations. For monitoring of toxic or flammable mixtures, it has special process cuvettes with safety devices like twin-seals and purge gas feeds. The heatable cuvettes made of corrosive-resistant materials have a high pressure resistance. An automatic adjustment device an innovative operation concept and modern communication protocols make the MCS300P an all-purpose photometer, also for potentially explosive atmospheres.
Applications
  • Process control in chemical production, e.g. of vinylchloride, isocyanate, polycarbonate, acrylic acid, adipic acid
  • Raw gas monitoring in waste incineration
  • Monitoring of flue gas conditioning
 
Technical specification
  Measuring principle   gas filter correlation, interference filter correlation  
  Measuring components   (C2H5)3N, (CH3)3SiCl, Br2, C2Cl4, C2H2, C2H2Cl2, C2H3Cl, C2H4, C2H4Cl2, C2H5OH, C2H6, C2HBrClF3, C2HCl3, C3F5ClOH, C3F6, C3F6O, C3H6, C3H7OH, C3H8, C4H10, C4H8, C4H9NH3, C6H4Cl2, C6H5CHO, C6H5Cl, C6H5NO2, CCl2F2, CCl4, CH2Cl2, CH3CHO, CH3COOC2H3, CH4, CHCl3, CHClF2, Cl2, CO, CO2, COCl2, COS, CS2, H2O, HCl, HCN, HF, N2O, NH3, NO, NO2, SF6, SiF4, SO2, UF6  
  Number of components   6  
  Remark   more than 60 measuring components are available, measuring ranges depend on application and combination of measuring components  
  Sample gas temperature   50 ... 200 °C (122 ... 392 °F)  
  Sample gas pressure   0.8 ... 60 bar  
  Ambient temperature   5 ... 40 °C (41 ... 104 °F)  
  Electrical safety   CE  
  Enclosure rating   Housing: IP 65
Cuvette: IP 20
 
  Analogue outputs   2 outputs:
0/4 ... 22 mA, 500 Ohm, electrically isolated, max. number of outputs depends on application
 
  Analogue inputs   2 inputs:
0/4 ... 22 mA, 100 Ohm, electrically isolated, max. number of inputs depends on application
 
  Digital outputs   5 outputs:
2 power relays, electrically isolated; 3 outputs, floating; max. number of outputs depends on application
 
  Digital inputs   4 inputs:
open contacts, floating; max. number of inputs depends on application
 
  Interfaces   RS-232 (9-pole), RS-422/RS-485, Ethernet  
  Bus protocol   Ethernet TCP/IP, PROFIBUS (Option), MODBUS (Option), OPC  
  Operation   via operation unit of analyzer, 2 operation levels  
  System components   analyzer, sampling probe, sample gas line, sample point switching, sample conditioning  
  Test functions   automatic control cycle for zero and span, internal adjustment unit (option)  
     